home

Load cell - CWH

list

  • Easy installation with hole in center.
  • Designed for use in civil engineering measurement, these loads on tunnel supports and soil pressure on protective Walls to aid control in construction projects.
  • catalog

     

    qna

    Specifications

    Specifications Accuracy
    Rated capacity(R.C) 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf, 50tf, 100tf, 200tf, 300tf
    Rated output(R.O) 1mV/V±0.4%
    Nonlinearity 1% of R.O.
    Hysteresis 1% of R.O.
    Repeatability 0.2% of R.O.
    Zero balance ±2% of R.O.
    Temperature effect, on rated output 0.05% of LOAD/10℃
    Temperature effect, on zero balance 0.1% of R.O./10℃
    Temperature range, compensated -10~60℃
    Temperature range, safe -20~80℃
    Terminal resistance input 700 ±50Ω
    Terminal resistance output 700 ±2Ω
    Insulation resistance bridge/case 2000MΩ
    Excitation recommended 10V
    Safe overload 150% R.C
    Cable length Φ7mm 4core, 3m

     

    Dimensions Table

    CWH.png

    Capacity ΦA ΦB ΦC D E F G Weight(kg)
    500kgf (4.903KN) 10 24 40 50 18 2x4-M4 DP10 1 0.5
    1tf (9.807KN) 18 55 62 70 44 2x8-M5 DP10 2 1
    2tf (19.61KN) 18 55 62 70 44 2x8-M5 DP10 2 1
    3tf (29.42KN) 18 55 62 70 44 2x8-M5 DP10 2 1
    5tf (49.03KN) 18 55 62 70 44 2x8-M5 DP10 2 1
    10tf (98.07KN) 18 55 62 80 44 2x8-M5 DP10 2 1.3
    20tf (196.1KN) 43 68 96 80 56 2x8-M6 DP10 3 3
    50tf (490.3KN) 80 112 130 110 96 2x6-M8 DP10 3 11
    100tf (980.7KN) 85 118 158 110 102 2x6-M12 DP10 3 13
    200tf (1.961MIN) 120 162 240 120 140 2x6-M12 DP12 3 25
    300tf (2.942MIN) 120 179 240 120 150 2x6-M12 DP15 3 26
    500tf (4.903MIN) 150 227 265 200 190 2x12-M12 DP15 8 30

    ★Specifications are subiect to change without notice.