home

Load cell - UM,UMA

list

  • Compression or Tension load cell.
  • These load cells are extremely small and lightweight.
  • catalog

     

    qna

    um,uma.jpg

    Specifications

    Specifications Accuracy
    UM UMA
    Rated capacity (R.C.) 50kgf, 100kgf, 200kgf, 500kgf, 1tf, 2tf
    (490.3N, 980.7N, 1.961kN, 4.903kN, 9.807kN, 19.61kN)
    50, 100, 200, 500kgf, 1tf, 2tf
    (490.3N, 980.7N, 1.961kN, 4.903kN, 9.807kN, 19.61kN)
    Rated output (R.O.) 2mV/V±0.4% 2mV/V
    Nonlinearity 0.15% of R.O.
    Hysteresis 0.1% of R.O.
    Repeatability 0.05% of R.O.
    Zero balance ±2% of R.O.
    Temperature effect,
    on rated output
    0.1% of LOAD/10℃
    Temperature effect,
    on zero balance
    0.05% of R.O./10℃
    Temperature range, compensated -10~70 C
    Temperature range, safe -10~80℃
    Terminal resistance input 350 ±50Ω 350 ±30Ω
    Terminal resistance output 350 ±2Ω
    Insulation resistance bridge/case 2000MΩ
    Excitation recommended 10V
    Safe overload 150% R.C 120% R.C
    Cable length Φ5mm 4core, 3m